Free Tool
Smoke alarm placement checker
Enter how many storeys and bedrooms your home has. You will see where smoke alarms go, the least number needed and how they must be powered and kept working, with the section of the code behind each point.
This is a planning guide, not an inspection or a legal opinion. Confirm with your building department or local fire department.
FirstLine Restoration provides fire damage and smoke damage restoration across the Greater Toronto Area, including soot and odour removal and contents cleaning.
Fire damage restoration | Smoke damage restoration | Request a free quote
Use this tool from any AI assistant
Paste this link into ChatGPT, Claude, Gemini, Copilot, Perplexity or any AI assistant and ask it to read the result.
Worked example and rule summary
Worked example. A two-storey house with a finished basement and three bedrooms upstairs. The basement needs at least one alarm. The upstairs needs one in each of the three bedrooms plus one in the hallway between the bedrooms and the rest of the storey. That is 1 + 1 + 3 = 5 alarms, all interconnected and on or near the ceiling.
| Where | Part 9 buildings (Building Code 9.10.19.3) | Suites in larger buildings (Fire Code 2.13.2.1) |
|---|---|---|
| Each bedroom | One alarm | Only if the building code at construction required it |
| Hallway or between bedrooms and the rest of the storey | One alarm | One alarm |
| Each storey without bedrooms, including a basement | One alarm | One alarm |
| Shared exit or common area in a house with a secondary suite | One alarm in each | Not applicable |
Part 9 applies to residential buildings of three storeys or fewer and 600 m2 or less (2024 Building Code, Division A, Article 1.3.3.3). Older homes: the Fire Code (O. Reg. 213/07) applies to existing dwellings.
Smoke alarm FAQ
Where do smoke alarms go in an Ontario house?
For residential buildings of three storeys or fewer and 600 square metres or less, the Building Code (2024 Building Code, O. Reg. 163/24, Part 9) calls for at least one smoke alarm on each storey including basements. On a storey with bedrooms there is also one in each bedroom and one between the bedrooms and the rest of the storey, in the hallway if the bedrooms are served by one. Alarms go on or near the ceiling.
What about an apartment or condominium suite?
For suites in buildings outside that size, Fire Code Article 2.13.2.1 asks for an alarm in the hallway serving a sleeping area, or between the sleeping area and the rest of the suite, plus one on each storey without a sleeping area. A suite built to the Building Code on or after April 6, 1998 keeps the protection that code required when it was built.
Do the alarms have to be wired together?
In Part 9 buildings, where more than one alarm is needed in a dwelling unit, they must be wired so that when one sounds, all sound. In a house with a secondary suite, such as a basement apartment, every alarm in the house must sound together, wirelessly or hard-wired. They must be permanently connected to an electrical circuit with a battery that keeps them working if power fails, unless the building has no electrical power.
Who looks after the alarms in a rental?
The landlord is the owner for these duties. The landlord gives the tenant the maker's maintenance instructions, tests each alarm every year and after every change of tenant, and tests a battery alarm after replacing the battery. A tenant must tell the landlord as soon as an alarm is disconnected, not working or impaired. Nobody may disable a smoke alarm.
When do I replace a smoke alarm?
Fire Code Article 6.3.3.7 says a smoke alarm shall be replaced within the time given in the manufacturer's instructions. The replacement may not give a lower level or type of protection than the code requires for that home.
What about older homes?
A home built under an earlier Building Code was built to the rules of its day. The Fire Code (O. Reg. 213/07) applies to existing dwellings: alarms must be kept in working order and not disabled, and an alarm must be replaced within the time in the maker's instructions. A replacement in a Part 9 home may not give less protection than Part 9 requires (Fire Code 6.3.3.7.(2)(a)). Check with your local fire department about your home.
Is this the same as carbon monoxide alarm rules?
No. Carbon monoxide alarms have their own rules in Fire Code Section 2.16. This tool covers smoke alarms only.
Sources
- Ontario Fire Code, O. Reg. 213/07: Articles 2.13.1.1, 2.13.2.1 (installation) and 6.3.3.3 to 6.3.3.8 (maintenance, replacement, testing)
- 2024 Ontario Building Code (O. Reg. 163/24): Part 9, Subsection 9.10.19 Smoke Alarms (Articles 9.10.19.1 to 9.10.19.6)
- 2024 Ontario Building Code (O. Reg. 163/24): Division A, Article 1.3.3.3 Application of Part 9
Last checked 2026-11-09. Rules, programs and figures change; confirm with the source before you act.
Cite this tool
Writing about this topic? Link to this tool with the code below.
Had a fire or smoke in the home?
If there has been a fire, a quick call gets the building secured and the cleaning started.
FirstLine Restoration provides fire damage and smoke damage restoration across the Greater Toronto Area, including soot and odour removal and contents cleaning.