Indoor humidity target by outdoor temperature (Firstline Restoration) Inputs: - outdoor_temp: -20 C - current_rh: 45 per cent Result: Highest indoor humidity at this outdoor temperature: 25 per cent or lower At an outdoor temperature of -20 C the table gives a maximum of 25 per cent relative humidity indoors (band -23 to -18 C, indoor air at 21 C). On an exact band edge this tool uses the lower value. Your reading Your reading of 45 per cent is above the 25 per cent limit for this outdoor temperature, so windows are likely to show condensation. Lowering humidity, for example with exhaust fans, a dehumidifier, and less indoor drying of laundry, would bring it down. Full table, indoor air at 21 C - Outdoor -7 to 4 C: indoor relative humidity at or below 40 per cent - Outdoor -12 to -7 C: indoor relative humidity at or below 35 per cent - Outdoor -18 to -12 C: indoor relative humidity at or below 30 per cent - Outdoor -23 to -18 C: indoor relative humidity at or below 25 per cent - Outdoor -29 to -23 C: indoor relative humidity at or below 20 per cent - Outdoor below -29 C: indoor relative humidity at or below 15 per cent What Health Canada says - Keep relative humidity between 30 and 50 per cent, using a dehumidifier as necessary. - Moisture condensing on cold surfaces such as windows is a sign that a dehumidifier may be needed. - Dry window frames and sills daily, keep window coverings open so warm air reaches the glass, and unplug humidifiers if windows are wet. Note The temperature table is aimed at limiting window condensation. On very cold days its figure is below the Health Canada 30 to 50 per cent year-round range, so use it as a winter limit for the windows rather than a target to hold all year. Damp windows, a musty smell or mould? We provide mould remediation and water damage restoration: finding the moisture source, containing and removing mould, and drying the space. Get a quote for an assessment. Call 24/7: (416) 900-3508. Mould remediation: https://firstlinerestoration.com/mold-remediation/ Water damage restoration: https://firstlinerestoration.com/water-damage-restoration/ Limits: Planning guide only. The table is aimed at limiting window condensation at an indoor temperature of 21 C. A hygrometer reading is only as good as the meter. Source: Recommended maximum indoor relative humidity by outdoor air temperature, at an indoor air temperature of 21 C (table in the Gentek window condensation booklet, which cites an industry source): https://www.gentek.ca/wp-content/uploads/sites/2/2023/01/Gentek-Condensation-booklet_ENG.pdf ; Health Canada, Guide to addressing moisture and mould indoors (30 to 50 per cent range, condensation on cold surfaces, dehumidifier above 50 per cent): https://www.canada.ca/en/health-canada/services/publications/healthy-living/addressing-moisture-mould-your-home.html Tool: https://firstlinerestoration.com/indoor-humidity-target-by-outdoor-temp/ Free quote: https://firstlinerestoration.com/indoor-humidity-target-by-outdoor-temp/#audience-quote